Electromechanical Cable Product Info

3/16” (4.80 mm) 4-Conductor Cable 4H18

3/16” (4.80 mm) 4-Conductor Cable 4H18

Properties

Cable Diameter:

0.186” +0.004” - 0.002”
(4.72 mm + 0.13mm -0.05mm)

Minimum Sheave Diameter:

14”
(36 cm)

Cable Stretch Coefficient:

4.25 ft/Kft/Klbs
(4.78 m/km/5KN)

ELECTRICAL

Maximum Conductor Voltage:

300 VDC

Recommended Operating Conductor Voltage:

Conductor AWG Rating:

23

Recommended Operating Conductor Voltage

1,500 MegΩ/Kft @ 1000VDC
(457 MegΩ/Km @ 1000VDC)

Armor Electrical Resistance:

6.7 Ω/Kft
(22.0 Ω/Km)

Mechanical

Minimum Insulation Resistance:

Ends Fixed:

3,100 lbs
(13.8 KN) Nominal

Maximum Suggested Working Tension:

1,550 lbs
(6.9 KN)

Number and Size of Wires:

Inner Armor:
18 x 0.0185”
(0.470 mm)
Outer Armor:
18 x 0.0248”
(0.630 mm)

Average Wire Breaking Strength:

Inner Armor:
72.6 lbs
(0.32 KN)
Outer Armor:
130.5 lbs
(0.58 KN)
Cable Type Core Description Cable Weight
Temp Rating Plastic Type Insulation Thickness Copper Construction Res Typical Cap Typical O.D. Each Tape Type In Air In H2O Spec. Gravity
°F
°C
in
mm
in
mm
Ω/Kft
ΩKm
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
4H18RPP 300*°
-18°
Poly 0.0075
0.191
7x0.0085
7x0.216
22.5
73.8
40
131
0.040
1.016
Poly 60
89
49
74