Electromechanical Cable Product Info

0.377” (9.58 mm) 3-Conductor Cable 3Q37

0.377” (9.58 mm) 3-Conductor Cable 3Q37

Properties

Cable Diameter:

0.377 +0.005” - 0.002”
(9.58 mm + 0.13mm -0.05mm)

Minimum Sheave Diameter:

22”
(56 cm)

Cable Stretch Coefficient:

1.6 ft/Kft/Klbs
(1.8 m/km/5KN)

ELECTRICAL

Maximum Conductor Voltage:

1200 VDC

Recommended Operating Conductor Voltage:

Conductor AWG Rating:

18

Recommended Operating Conductor Voltage

1,500 MegΩ/Kft @ 500VDC
(457 MegΩ/Km @ 500VDC)

Armor Electrical Resistance:

1.7 Ω/Kft
(5.6 Ω/Km)

Mechanical

Minimum Insulation Resistance:

Ends Fixed:

13,200 lbs
(58.74 KN) Nominal

Maximum Suggested Working Tension:

6,600 lbs
(29.37 KN)

Number and Size of Wires:

Inner Armor:
16 x 0.0425”
(1.08 mm)
Outer Armor:
20 x 0.0470”
(1.19 mm)

Average Wire Breaking Strength:

Inner Armor:
383 lbs
(1.71 KN)
Outer Armor:
469 lbs
(2.09 KN)
Cable Type Core Description Cable Weight
Temp Rating Plastic Type Insulation Thickness Copper Construction Res Typical Cap Typical O.D. Each Tape Type In Air In H2O Spec. Gravity
°F
°C
in
mm
in
mm
Ω/Kft
ΩKm
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
3Q37RP 300*°
-18°
Poly 0.0230
0.584
7x0.0152
7x0.386
7.1
23.3
47
154
0.096
2.438
Dacron® 233
347
49
74
N/A