Electromechanical Cable Product Info

2Q37-EHS-EcoSeal Coaxial Cable

2Q37-EHS-EcoSeal Coaxial Cable

Properties

Cable Diameter:

0.374 +0.005” - 0.005”
(9.50mm + 0.13mm -0.13mm)

Minimum Sheave Diameter:

26"
(66 cm)

Cable Stretch Coefficient:

ELECTRICAL

Maximum Conductor Voltage:

1500 VDC

Recommended Operating Conductor Voltage:

Conductor AWG Rating:

14

Recommended Operating Conductor Voltage

1,500 GΩ/Kft @ 500VDC
5.0 GΩ/Km @ 500VDC

Armor Electrical Resistance:

3.4 Ω/Kft
11.3 Ω/Km

Mechanical

Minimum Insulation Resistance:

Ends Fixed:

8200 lbs
(36.5 kN) Nominal

Maximum Suggested Working Tension:

5000 lbs
(22.2 kN)

Number and Size of Wires:

Inner Armor:
21x0.028"
(0.711mm)
Outer Armor:
14x3W Strand 0.043"
(1.092mm)

Average Wire Breaking Strength:

Inner Armor:
210 lbs
(0.94 kN)
Outer Armor:
318 lbs
(1.41 kN)
Cable Type Core Description Cable Weight
Temp Rating Plastic Type Insulation Thickness Copper Construction Res Typical Cap Typical O.D. Each In Air In H2O Spec. Gravity
°F
°C
in
mm
in
mm
Ω/Kft
ΩKm
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
2Q37CTZZ-EHStZZ 400*°
-18°
FEP 0.025
0.635
0.067 compacted (7 wires)
1.702 compacted (7 wires)
2.8
9.2
54
177
0.117
2.972
167
248
138
205
2Q37CTZZ-EHStZZ 400*°
-18°
ETFE 0.013
0.330
0.067 compacted (7 wires)
1.702 compacted (7 wires)
4.1
13.3
175
575
0.159
4.038
167
248
138
205
2Q37CTZZ-EHStZZ 400*°
-18°
M-ETFE 0.012
0.305
45x0.0080
45x0.203


0.183
4.648
167
248
138
205