Electromechanical Cable Product Info

1Q36-EHS EcoSeal®

1Q36-EHS EcoSeal®

Properties

Cable Diameter:

0.359” +0.004” - 0.002”
(9.12mm + 0.10mm -0.05mm)

Minimum Sheave Diameter:

26”
(66 cm)

Cable Stretch Coefficient:

1.55 ft/Kft/Klbs
(1.74 m/Km/5KN)

ELECTRICAL

Maximum Conductor Voltage:

1,500 VDC

Recommended Operating Conductor Voltage:

Conductor AWG Rating:

15

Recommended Operating Conductor Voltage

1,500 MegaΩ/Kft @ 1000VDC
(457 MegaΩ/Km @ 1000VDC)

Armor Electrical Resistance:

4.5 Ω/Kft
(14.76 Ω/Km)

Mechanical

Minimum Insulation Resistance:

Ends Fixed:

9000 lbs
(40.0 KN) Nominal

Maximum Suggested Working Tension:

5000 lbs
(22.2 KN)

Number and Size of Wires:

Inner Armor:
11 x 0.0470”
(1.194 mm)
Outer Armor:
14 x 3W Strand .0430
(1.092 mm)

Average Wire Breaking Strength:

Inner Armor:
542 lbs
(2.4 KN)
Outer Armor:
191 lbs
(0.85 KN)
Cable Type Core Description Cable Weight
Temp Rating Plastic Type Insulation Thickness Copper Construction Res Typical Cap Typical O.D. Each In Air In H2O Spec. Gravity
°F
°C
in
mm
in
mm
Ω/Kft
ΩKm
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1Q36PTZ-EHStZ4 °
-18°
ETFE 0.019
0.483
19x0.0142
19x0.361
2.8
0.2
54
177
0.136
3.454
171
232
141
168
1Q36PTZ-EHStZ4 400*°
-18°
FEP 0.0135
0.343
19x0.0142
10x0.361
2.8
9.2
54
177
0.098
2.489
171
232
141
168