Electromechanical Cable Product Info

1/4

1/4" (6.55 mm) Monoconductor 1Q25-FO

Properties

Cable Diameter:

0.249” +0.005” - 0.002”
(6.32mm + 0.13mm -0.05mm)

Minimum Sheave Diameter:

16”
(41 cm)

Cable Stretch Coefficient:

1.8 ft/Kft/Klbs
(2.02 m/Km/5KN)

ELECTRICAL

Maximum Conductor Voltage:

1,000 VDC

Recommended Operating Conductor Voltage:

Conductor AWG Rating:

19

Recommended Operating Conductor Voltage

1,500 MegaΩ/Kft @ 500VDC
(457 MegaΩ/Km @ 500VDC)

Armor Electrical Resistance:

3.3 Ω/Kft
(10.8 Ω/Km)

Mechanical

Minimum Insulation Resistance:

Ends Fixed:

6,600 lbs
(29.37 KN) Nominal

Maximum Suggested Working Tension:

3,300 lbs
(14.68 KN)

Number and Size of Wires:

Inner Armor:
12 x 0.0310”
(0.787 mm)
Outer Armor:
14 x 0.0425”
(1.080 mm)

Average Wire Breaking Strength:

Inner Armor:
204 lbs
(0.91 KN)
Outer Armor:
383 lbs
(1.71 KN)
Cable Type Core Description Cable Weight
Temp Rating Plastic Type Insulation Thickness Copper Construction Res Typical Cap Typical O.D. Each In Air In H2O Spec. Gravity
°F
°C
in
mm
in
mm
Ω/Kft
ΩKm
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1Q25YZ-FO 500*°
-18°
FEP 0.023
0.584
18x0.0085
8.5
27.9
78
256
0.109
2.770
117
175
97
144