Electromechanical Cable Product Info

0.36

0.36" (9.068 mm) Monoconductor 1Q36-FO-S77

Properties

Cable Diameter:

0.357" +0.005" -0.002"
(9.068mm +0.13mm -0.05mm)

Minimum Sheave Diameter:

22"
(56 cm)

Cable Stretch Coefficient:

1.27 Kft/Klbs
(1.43 m/Km/5KN)

ELECTRICAL

Maximum Conductor Voltage:

1,500 VDC

Recommended Operating Conductor Voltage:

Conductor AWG Rating:

11

Recommended Operating Conductor Voltage

1,500 MegaΩ/Kft @ 500VDC
(457 MegaΩ/Km @ 500VDC)

Armor Electrical Resistance:

8.85 Ω/Kft
(29.05 Ω/Km)

Mechanical

Minimum Insulation Resistance:

Ends Fixed:

10,100 lbs
(44.94 KN) Nominal

Maximum Suggested Working Tension:

5,050 lbs
(22.47 KN)

Number and Size of Wires:

Inner Armor:
18 x 0.039"
(0.991 mm)
Outer Armor:
23 x 0.039"
(0.991 mm)

Average Wire Breaking Strength:

Inner Armor:
280 lbs
(1.25 KN)
Outer Armor:
280 lbs
(1.25 KN)
Cable Type Core Description Cable Weight
Temp Rating Plastic Type Insulation Thickness Copper Construction Res Typical Cap Typical O.D. Each In Air In H2O Spec. Gravity
°F
°C
in
mm
in
mm
Ω/Kft
ΩKm
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1Q36YZ-FO-S77 500*°
-18°
ETFE 0.032
0.800
14x0.0253
19x0.643
1.43
4.68
144
472
0.208
5.27
233
347
193
287