Electromechanical Cable Product Info


5/16" (8.18 mm) Monoconductor 1N32-GeoSteam

Properties

Cable Diameter:

0.322” +0.005” - 0.002”
(8.18mm +0.13mm -0.05mm)

Minimum Sheave Diameter:

18”
(46 cm)

Cable Stretch Coefficient:

1.2 ft/Kft/Klbs
(1.35 m/Km/5KN)

ELECTRICAL

Maximum Conductor Voltage:

1,500

Recommended Operating Conductor Voltage:

Conductor AWG Rating:

15

Recommended Operating Conductor Voltage

1,500 MegaΩ/Kft @ 500 VDC
(457 MegaΩ/Km @ 500VDC)

Armor Electrical Resistance:

2.1 Ω/Kft
(6.9 Ω/Km)

Mechanical

Minimum Insulation Resistance:

Ends Fixed:

12,000 lbs
(53.4 KN) Nominal

Maximum Suggested Working Tension:

6,000 lbs
(26.7 KN)

Number and Size of Wires:

Inner Armor:
12 x 0.0445”
(1.130 mm)
Outer Armor:
18 x 0.0445”
(1.130 mm)

Average Wire Breaking Strength:

Inner Armor:
442 lbs
(1.97 KN)
Outer Armor:
442 lbs
(1.97 KN)
Cable Type Core Description Cable Weight
Temp Rating Plastic Type Insulation Thickness Copper Construction Res Typical Cap Typical O.D. Each In Air In H2O Spec. Gravity
°F
°C
in
mm
in
mm
Ω/Kft
ΩKm
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1N32WG 600*°
-18°
ECA 0.0421
1.067
19x0.0142
19x0.361
3.2
10.5
46
151
0.155
3.937
195
290
161
240