Electromechanical Cable Product Info

7/32” (5.69 mm) Monoconductor 1N22

7/32” (5.69 mm) Monoconductor 1N22

Properties

Cable Diameter:

0.224” +0.005” - 0.002”
(5.69mm + 0.13mm -0.05mm)

Minimum Sheave Diameter:

14”
(36 cm)

Cable Stretch Coefficient:

2.5 ft/Kft/Klbs
(2.81 m/Km/5KN)

ELECTRICAL

Maximum Conductor Voltage:

1,200 VDC

Recommended Operating Conductor Voltage:

Conductor AWG Rating:

16

Recommended Operating Conductor Voltage

1,500 MegaΩ/Kft @ 1000VDC
(457 MegaΩ/Km @ 1000VDC)

Armor Electrical Resistance:

4.4 Ω/Kft
(14.4 Ω/Km)

Mechanical

Minimum Insulation Resistance:

Ends Fixed:

5,600 lbs
(24.9 KN) Nominal

Maximum Suggested Working Tension:

2,800 lbs
(12.5 KN)

Number and Size of Wires:

Inner Armor:
12 x 0.0310”
(0.787 mm)
Outer Armor:
18 x 0.0310”
(0.787 mm)

Average Wire Breaking Strength:

Inner Armor:
215 lbs
(0.96 KN)
Outer Armor:
215 lbs
(0.96 KN)
Cable Type Core Description Cable Weight
Temp Rating Plastic Type Insulation Thickness Copper Construction Res Typical Cap Typical O.D. Each In Air In H2O Spec. Gravity
°F
°C
in
mm
in
mm
Ω/Kft
ΩKm
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1N22PP 300*°
-18°
Poly 0.0245
0.622
19x0.0119
19x0.302
4.1
13.5
61
200
0.108
2.743
93
139
77
115
N/A
1N22PXZ 420*°
-18°
ETFE 0.0115
0.292
19x0.0119
19x0.302
4.1
13.5
61
200
0.108
2.743
94
140
78
116
N/A
1N22PXZ 420*°
-18°
TPX 0.0130
0.330
19x0.0119
19x0.302
4.1
13.5
61
200
0.085
2.159
94
140
78
116
N/A
1N22PTZ 500*°
-18°
ETFE 0.0245
0.622
19x0.0119
19x0.302
4.1
13.5
59
194
0.108
2.743
96
143
90
134
N/A
1N22PTZ 500*°
-18°
FEP 0.0115
0.330
19x0.0119
19x0.302
4.1
13.5
59
194
0.085
2.159
96
143
90
134
N/A