Cased Hole

Cased Hole
1N10

1/10"

  • Cable Diameter: 1/10 Inch
  • Suggested Working Tension: 500 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F
  • Conductor: 1 X 24 AWG
  • Special: Not intended for use in oil & gas wells
More Product Info
1N12

1/8"

  • Cable Diameter: 1/8 Inch
  • Suggested Working Tension: 800 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 500°F
  • Conductor: 1 X 24 AWG
  • Special: Not intended for use in oil & gas wells
More Product Info
1L18

3/16"

  • Cable Diameter: 3/16 Inch
  • Suggested Working Tension: 2,000 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 500°F
  • Conductor: 1 X 20 AWG
More Product Info
1K22

7/32"

  • Cable Diameter: 7/32 Inch
  • Suggested Working Tension: 2,800 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 420°F, 500°F
  • Conductor: 1 X 16 AWG
  • Special: 15/15 Armor Wire Package
More Product Info
1N22

7/32"

  • Cable Diameter: 7/32 Inch
  • Suggested Working Tension: 2,800 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 420°F, 500°F
  • Conductor: 1 X 16 AWG
  • Special: 12/18 Armor Wire Package
More Product Info
1N25

1/4"

  • Cable Diameter: 1/4 Inch
  • Suggested Working Tension: 3,650 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 420°F, 500°F
  • Conductor: 1 X 16 AWG
More Product Info
1N29-EHS

9/32"

  • Cable Diameter: 9/32 Inch
  • Suggested Working Tension: 5,100 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 420°F, 500°F
  • Conductor: 1 X 15 AWG
More Product Info
1N29-EEHS

9/32"

  • Cable Diameter: 9/32 Inch
  • Suggested Working Tension: 5,450 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 15 AWG
  • Special: Extra-Extra High Strength Armor Wire
More Product Info
1N32

5/16"

  • Cable Diameter: 5/16 Inch
  • Suggested Working Tension: 6,000 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 420°F, 500°F
  • Conductor: 1 X 15 AWG
More Product Info
1N32-EEHS

5/16"

  • Cable Diameter: 5/16 Inch
  • Suggested Working Tension: 7,375 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 500°F
  • Conductor: 1 X 15 AWG
  • Special: Extra-Extra High Strength Armor Wire
More Product Info
1N32-LR

5/16"

  • Cable Diameter: 5/16 Inch
  • Suggested Working Tension: 6,000 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 13 AWG
  • Special: Low resistance conductor package
More Product Info

Open Hole

Open Hole
3Q37

0.377"

  • Cable Diameter: 3/8 Inch
  • Suggested Working Tension: 6,600 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F
  • Conductor: 3 X 18 AWG
More Product Info
4H18

3/16"

  • Cable Diameter: 3/16 Inch
  • Suggested Working Tension: 1,550 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F
  • Conductor: 4 X 23 AWG
  • Special: Not intended for use in oil & gas wells
More Product Info
4H18-SS

3/16"

  • Cable Diameter: 3/16 Inch
  • Suggested Working Tension: 1,550 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F
  • Conductor: 4 X 23 AWG
  • Special: Stainless Steel Armor Wire, Not intended for use in oil & gas wells
More Product Info
7Q38

3/8"

  • Cable Diameter: 3/8 Inch
  • Suggested Working Tension: 6,550 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 7 X 20 AWG
More Product Info
7H42

7/16"

  • Cable Diameter: 7/16 Inch
  • Suggested Working Tension: 8,800 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 500°F
  • Conductor: 7 X 20 AWG
More Product Info
7J46

15/32"

  • Cable Diameter: 15/32 Inch
  • Suggested Working Tension: 9,550 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 420°F, 500°F
  • Conductor: 7 X 20 AWG
More Product Info
7H47-EHS

0.474"

  • Cable Diameter: .474 Inch
  • Suggested Working Tension: 12,250 lbs.
  • 1 Hour Max. Temp. Offerings: 300°F, 420°F, 500°F
  • Conductor: 7 X 20 AWG
  • Special: Trade name “Slammer”
More Product Info
7Q49-EHS

0.490"

  • Cable Diameter: .490 Inch
  • Suggested Working Tension: 12,875 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 7 X 20 AWG
  • Special: Reinforced “DuraSlam™” conductor core package.
More Product Info
7Q49-EEHS

0.490"

  • Cable Diameter: .490 Inch
  • Suggested Working Tension: 15,000 lbs.
  • 1 Hour Max. Temp. Offerings: 420°F, 500°F
  • Conductor: 7 X 20 AWG
  • Special: Extra-Extra High Strength Armor Wire, Reinforced “DuraSlam™” conductor core package.
More Product Info
7Q54-EEHS

0.548"

  • Cable Diameter: .548 Inch
  • Suggested Working Tension: 20,000 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 7 X 20 AWG
  • Special: Extra-Extra High Strength Armor Wire, Low resistance conductor package, Reinforced “DuraSlam™” conductor core package.
More Product Info

Sour Service

Sour Service
1N22-S75

7/32"

  • Cable Diameter: 7/32 Inch
  • Suggested Working Tension: 2,350 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 18 AWG
  • Special: Alloy armor wire package suitable for low levels of H²S & CO2
More Product Info
1N22-S77

7/32"

  • Cable Diameter: 7/32 Inch
  • Suggested Working Tension: 2,450 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 18 AWG
  • Special: Alloy armor wire package suitable for medium levels of H²S & CO2
More Product Info
1N22-MP35N

7/32"

  • Cable Diameter: 7/32 Inch
  • Suggested Working Tension: 2,600 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 18 AWG
  • Special: Alloy armor wire package suitable for high levels of H²S & CO2
More Product Info
1N25-S75

1/4"

  • Cable Diameter: 1/4 Inch
  • Suggested Working Tension: 3,100 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 16 AWG
  • Special: Alloy armor wire package suitable for low levels of H²S & CO2
More Product Info
1N25-S77

1/4"

  • Cable Diameter: 1/4 Inch
  • Suggested Working Tension: 3,250 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 16 AWG
  • Special: Alloy armor wire package suitable for medium levels of H²S & CO2
More Product Info
1N29-S75

9/32"

  • Cable Diameter: 9/32 Inch
  • Suggested Working Tension: 3,900 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 16 AWG
  • Special: Alloy armor wire package suitable for low levels of H²S & CO2
More Product Info
1N29-S77

9/32"

  • Cable Diameter: 9/32 Inch
  • Suggested Working Tension: 4,050 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 16 AWG
  • Special: Alloy armor wire package suitable for medium levels of H²S & CO2
More Product Info
1N32-S75

5/16"

  • Cable Diameter: 5/16 Inch
  • Suggested Working Tension: 4,850 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 15 AWG
  • Special: Alloy armor wire package suitable for low levels of H²S & CO2
More Product Info
1N32-S77

5/16"

  • Cable Diameter: 5/16 Inch
  • Suggested Working Tension: 5,000 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 15 AWG
  • Special: Alloy armor wire package suitable for medium levels of H²S & CO2
More Product Info

Geothermal (GeoSteam™)

Geothermal (GeoSteam™)
1N22WG

7/32"

  • Cable Diameter: 7/32 Inch
  • Suggested Working Tension: 2,800 lbs.
  • 1 Hour Max. Temp. Offerings: 600°F
  • Conductor: 1 X 16 AWG
  • Special: GeoSteam™ high temperature insulation package
More Product Info
1N32WG

5/16"

  • Cable Diameter: 5/16 Inch
  • Suggested Working Tension: 6,000 lbs.
  • 1 Hour Max. Temp. Offerings: 600°F
  • Conductor: 1 X 15 AWG
  • Special: GeoSteam™ high temperature insulation package
More Product Info
7J46WG

15/32"

  • Cable Diameter: 15/32 Inch
  • Suggested Working Tension: 9,550 lbs.
  • 1 Hour Max. Temp. Offerings: 600°F
  • Conductor: 7 X 20 AWG
  • Special: GeoSteam™ high temperature insulation package
More Product Info

Greaseless (EcoSeal®)

Greaseless (EcoSeal®)
EcoSeal®

0.359"

  • Cable Diameter: .36 Inch
  • Suggested Working Tension: 5,000 lbs.
  • 1 Hour Max. Temp. Offerings: 400°F
  • Conductor: 1 X 15 AWG
  • Special: Greaseless jacketed cable package
More Product Info
EcoSeal® Coaxial

0.374"

  • Cable Diameter: .374 Inch
  • Suggested Working Tension: 5,000 lbs.
  • 1 Hour Max. Temp. Offerings: 400°F
  • Conductor: 2 X 14/16 AWG
  • Special: Coaxial Conductor, Greaseless jacketed cable package
More Product Info

Fiber Optic

Fiber Optic
1Q25-FO

1/4"

  • Cable Diameter: 1/4 Inch
  • Suggested Working Tension: 3,300 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 19 AWG
  • Special: 1.17mm fiber optic enabled tube with up to 4 fibers
More Product Info
1Q25-FO-S75

1/4"

  • Cable Diameter: 1/4 Inch
  • Suggested Working Tension: 2,950 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 19 AWG
  • Special: Alloy armor wire package suitable for low levels of H²S & CO2, 1.17mm fiber optic enabled tube with up to 4 fibers
More Product Info
1N32-FO

5/16"

  • Cable Diameter: 5/16 Inch
  • Suggested Working Tension: 6,000 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 16 AWG
  • Special: 1.65mm fiber optic enabled tube with up to 4 fibers
More Product Info
1Q36-FO

0.36"

  • Cable Diameter: .357 Inch
  • Suggested Working Tension: 6,550 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 11 AWG
  • Special: 2.4mm fiber optic enabled tube with up to 6 fibers
More Product Info
1Q36-FO-S75

0.36"

  • Cable Diameter: .357 Inch
  • Suggested Working Tension: 5,100 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 11 AWG
  • Special: Alloy armor wire package suitable for low levels of H²S & CO2, 2.4mm fiber optic enabled tube with up to 6 fibers
More Product Info
1Q36-FO-S77

0.36"

  • Cable Diameter: .357 Inch
  • Suggested Working Tension: 5,050 lbs.
  • 1 Hour Max. Temp. Offerings: 500°F
  • Conductor: 1 X 11 AWG
  • Special: Alloy armor wire package suitable for medium levels of H²S & CO2, 2.4mm fiber optic enabled tube with up to 6 fibers
More Product Info